Looks like you're using an unsupported browser, so some features might not work. We recommend upgrading your browser for a better experience.

Blitz 15083 SBC I-Color Boost Controller Black Spec R

Manufacturer: Blitz
Product # {{ productPartNumber }}
Discontinued / No Longer Available
This item has been discontinued by the manufacturer, and it can no longer be ordered or purchased.

Discontinued

Manufacturer: Blitz
Product # {{ productPartNumber }}
Product not eligible for promotional or discount codes.

Discontinued

Product not eligible for promotional or discount codes.

Description

This product's purpose is to control the boost of the turbocharger and improve the output of the engine. A state of the art digital controller for an accurate gain in boost pressure, which controls either one (Spec S) or two (Spec R) highly efficient solenoids which achieves a minimum over shoot on peak boost and stable boost pressure.

sbcicolor_startup.gif


* Boost control & power meter function.

An added function, the Result graph, which displays the results of power, torque, boost, and A/F overlapping to each other on one screen. It has a function as al logger according to the RPM to compare a maximum of three channels on the horizontal axis that are power, torque, boost and A/F.

* The ultimate boost controller

The known full auto function evolves further in the SBC i-D series. A still more precise control is added to the auto boost setup. In addition to the new full auto function in which the self-learning method can be chosen in three steps, a boost according to the RPM and speed is possible to setup to match on all the stages.

* Full color (65.000 colors)

The graphics that the full color display made it possible are; such as displaying from analog to digital meter, graph comparison display and a possibility to produce a variation of back ground images. If the optional TEMP sensor and PRESS sensor are connected, it is also possible to display water temperature or oil temperature and oil pressure. If the optional A/F Box is connected you will be able to display real time A/F ratio.

Note: There are 2 plugs for optional sensors. One is strictly for Temperature and the other is for EITHER Pressure OR A/F. The unit is NOT able to display both Pressure and A/F.

Optional Sensor: CODE 19210 Temp Sensor Set USD 135.00

CODE 19211 Press Sensor Set USD 135.00

CODE 15063 A/F Box with O2 USD 550.00

* Digital display:

A total of 12 data (Boost, Tacho, Speed, Power, Temp (Oil/Water), Fuel Press, Oil Press, Data 1 ~3 (A separate harness is necessary) can be monitored and it can display simultaneously on screen a maximum of six data.

A/F can be displayed at the AUX port or at the external voltage port Data 1~3.

The sensors are necessary to purchase separately.

* Analog display:

The Boost, Tacho, Speed, Power, Temp (Oil/Water), A/F, Fuel Press and Oil Press are reproduced as an analog meter image at the LCD. It can monitor a maximum of 4 data, including the digital displays at the screen, and the boost set up is at will. Moreover, the background can also be chosen from a white, black, carbon, and blue.

* Multi-angle display function

The display of the LCD can be set as left, right and perpendicular (the LCD at the top) operation angles. By selecting any one of these three angles, the switches also change automatically to the related angle.

* Convenient functions

It has a full load of convenient functions, such as a peak display, independent warning setup by source, maximum of 10 minutes of record/replay option (replay option can convert the unit displayed), back light adjustment, dimmer option, contrast adjustment and language selection.

Optional A/F display option

If the optional A/F amplifier unit is connected, the A/F ratio can be measured and monitored, which can compare with boost or other sources. Thus, the boost setting can be broadened.

* Sequential valve control (Spec R only):

Two-solenoid valves operate sequentially depending on the valve-open ratio. Mainly, the first valve will do most of the work at low valve-open ratio and at high valve-open ratio; the second valve will come to play.

* Automatic correction of boost pressure (Initial learning):

It will automatically correct to the desired boost pressure that has been configured. A C mark will change color from RED to WHITE when the correction cycle (DUTY value) reaches the desired value. While the C mark is lighted, the SCRAMBLE MODE or the SPEED MAP MODE will not take effect on the used channel. However, the boost control will take effect even if the C mark does not change to WHITE color. This time, to perform the initial learning smoother, the normal, mild and slow function has been added. The Automatic correction of boost pressure is not applicable on manual mode.

Fuel Consumption Function

With the latest model of the SBC i-Color, a fuel consumption display has been added. This function allows you to see how much fuel you are using in real time. There are a few different situations in which the fuel consumption can be calculated. Instant, Average, and Distance fuel consumption can be displayed. We utilize our own original calculation based on the generated horsepower reading.

External voltage input

It is possible to display, record, and replay by inputting an external voltage of 0-16V up to three channels. It is possible to change the voltage scale from -999 ~9999. It is also possible to arbitrary setup the value. Therefore, it can be used to record the throttle voltage, airflow voltage, water temp and replay for reference as a setting tool. The external voltage input harness is sole separately.

Ships out in 24 hours

Copyright 2024 Concept Z Performance